Generator Automatic Transfer Switches

Send Inquiry
Generator Automatic Transfer Switches
Details
● Product type: DIN rail dual power automatic transfer switch
● Rated current: 16A / 25A / 32A / 40A / 50A / 63A
● Rated insulation voltage Ui: AC690V, 50Hz/60Hz
● Rated voltage Ue: AC400V, 50Hz/60Hz
● Rated control voltage Us: AC220V or AC110V, 50Hz/60Hz
● Control voltage operating range: 85%Us-110%Us
Category
Automatic Transfer Switches
Share to
Description

Product Overview

 

This DIN rail dual power automatic transfer switch is designed to switch loads between the normal power source and a backup power source when the main supply fails. It is suitable for AC 50Hz or 60Hz distribution systems and generator networks with rated voltage AC400V, helping maintain continuous operation in circuits where power interruption should be minimized.

 

The compact ATS integrates a transfer switching device and controller, supporting automatic and manual operation. Its DIN rail structure makes it practical for PZ30 distribution boxes, control cabinets, and low-voltage panels that require reliable standby power changeover.

 

Key Features

 

  • Generator backup switching: Transfers the load from normal power to standby power when the normal supply fails.
  • DIN rail mounting: Compact rail-type design for easy installation in distribution boxes and control cabinets.
  • Fast transfer performance: Contactor switching time, operation conversion time, return conversion time, and power-off time are each below 50ms.
  • Multiple current ratings: Covers 16A, 25A, 32A, 40A, 50A, and 63A for small and medium distribution circuits.
  • Flexible pole selection: 2P, 3P, and 4P models are available for different wiring systems.
  • Control voltage options: Supports AC220V or AC110V rated control voltage with normal operation from 85%Us to 110%Us.
  • PC grade operation: Switches and carries normal current and fault current without generating short-circuit current.

 

Main Technical Specifications

 

Item

Specification

Product type

DIN rail dual power automatic transfer switch

Rated current

16A / 25A / 32A / 40A / 50A / 63A

Rated insulation voltage Ui

AC690V, 50Hz/60Hz

Rated voltage Ue

AC400V, 50Hz/60Hz

Rated control voltage Us

AC220V or AC110V, 50Hz/60Hz

Control voltage operating range

85%Us-110%Us

Grade

PC grade

Use category

AC-33iB / AC-31B

Poles

2P / 3P / 4P

Weight

2P: 0.62kg; 3P: 0.71kg; 4P: 0.81kg

Electrical / manual life

Electrical life: 2000 operations; manual operation: 5000 operations

Rated short-circuit current Iq

50kA

Short-circuit protection device

RT16-00-63A

Rated impulse withstand voltage

8kV

Transfer time

Contactor switching, operation conversion, return conversion, and power-off time: <50ms

Applicable standard

GB/T14048.11 / IEC60947-6-1

 

Recommended Applications

 

This ATS is suitable for distribution and backup power systems where a generator or standby source must supply the load after normal power failure.

  • Small generator backup power systems
  • Residential and commercial distribution boxes
  • PZ30 distribution boxes and DIN rail panels
  • Control cabinets and low-voltage power panels
  • Lighting, security, communication, and equipment standby circuits
  • Facilities where power outages are not allowed or should be reduced

 

Installation Conditions

 

  • Ambient temperature should not exceed +40°C, should not be lower than -5°C, and the 24-hour average should not exceed +35°C.
  • Installation altitude should not exceed 2000m.
  • At +40°C, relative humidity should not exceed 50%; higher humidity is permitted at lower temperature with condensation protection as needed.
  • Pollution degree: level 3 according to GB/T14048.11 / IEC60947-6-1.
  • The product can be mounted vertically in a control cabinet or distribution cabinet with proper clearance.

 

Operation and Maintenance Notes

 

  • Use automatic mode during normal operation; manual mode is mainly for inspection, maintenance, or special operation.
  • Before installation, check product integrity and operate the handle to confirm the drive unit is flexible.
  • The control circuit voltage should be AC220V or AC110V, and copper wire cross-section should not exceed 2.0mm2.
  • Install appropriate circuit breakers according to the power distribution system requirements.
  • Maintenance and inspection should be performed by qualified professionals after all power sources are disconnected.
  • First maintenance is recommended within 6 months after use, then at least once per year.

 

Model Selection Notes

 

When selecting the correct model, confirm the rated current, pole number, control voltage, normal power source, backup generator source, distribution box layout, and required operation mode. For generator backup systems, also confirm voltage stability, control voltage, and the transfer logic required by the project.

 

Request a Quote

 

Need help choosing a DIN rail ATS for your generator backup project? Send the rated current, pole configuration, control voltage, normal/standby power type, application scenario, and order quantity. Our team can provide model guidance, technical data, wiring support, and quotation options.

Hot Tags: generator automatic transfer switches, China generator automatic transfer switches manufacturers, suppliers, factory, CB Automatic Transfer Switches, Dual Power Automatic Switching, Isolated Automatic Transfer Switch, Mini Automatic Transfer Switches, Mini Push type Ultra thin Automatic Switching, Rail Mounted Dual Power Switch