Automatic Aerosol Spray Fire Extinguisher

Send Inquiry
Automatic Aerosol Spray Fire Extinguisher
Details
● Extinguishing agent: 10g
● Protected space: <=0.4m3
● Discharge time: <=6s
● Working environment: -50°C to +90°C
● Agent validity period: 10 years
● Installation method: Standard guide rail fixing / 3M adhesive
Category
Current Limiting Fire Protector
Share to
Description

Product Overview

 

The QRR series is a compact heat aerosol fire extinguishing device designed for small enclosed spaces where rapid local fire suppression is required. After activation, the solid aerosol-generating agent produces fine extinguishing aerosol particles that disperse through the protected space and help interrupt combustion through physical and chemical suppression mechanisms.

 

This Automatic Aerosol Spray Fire Extinguisher is suitable for electrical cabinets, control boxes, distribution panels, battery compartments, and other compact equipment enclosures. Its small body, optional appearance styles, and flexible installation methods make it practical for OEM equipment and retrofit fire protection projects.

 

Key Features

 

  • Compact enclosure protection: Designed for small protected spaces up to 0.4m3 or 0.8m3 depending on agent quantity.
  • Fast aerosol discharge: Discharge time is no more than 6 seconds for rapid local suppression response.
  • Wide working temperature range: Operates from -50°C to +90°C for demanding equipment environments.
  • Long service life: Agent validity period is 10 years under proper storage and operating conditions.
  • Flexible installation: Supports standard guide rail mounting or 3M adhesive installation.
  • Multiple appearance styles: LT, TB, and LK housing options are available for different equipment layouts.
  • Environment-conscious formula: The aerosol agent is designed to be non-toxic, non-corrosive, and free from ozone-layer depletion concerns.

 

Main Technical Specifications

 

Item

10g Model

20g Model

Product series

QRR heat aerosol fire extinguishing device

QRR heat aerosol fire extinguishing device

Extinguishing agent

10g

20g

Protected space

<=0.4m3

<=0.8m3

Discharge time

<=6s

<=6s

Working environment

-50°C to +90°C

-50°C to +90°C

Agent validity period

10 years

10 years

Installation method

Standard guide rail fixing / 3M adhesive

Standard guide rail fixing / 3M adhesive

Oxidizer / nitrate content

50%-58%

50%-58%

Packing quantity

100 pcs

100 pcs

Carton weight

5.5 kg/carton

6.5 kg/carton

 

Available Model Styles

 

Model style

Example model

Product size

LT style

QRR-0.01G(-2/10RLT)

84.5 x 18 x 60 mm

TB style

QRR-0.01G(-2/10BTB)

87.5 x 18 x 59 mm

LK style

QRR-0.01G(-2/10RLK)

77 x 18 x 65.5 mm

 

Recommended Applications

 

This automatic aerosol fire suppression device is intended for compact enclosed spaces where electrical equipment, components, or stored energy systems require localized protection.

  • Electrical control cabinets and distribution boxes
  • Switchgear compartments and terminal boxes
  • Battery cabinets, battery packs, and energy storage modules
  • Communication equipment and telecom enclosures
  • Automation equipment, machine control boxes, and OEM devices
  • Small sealed or semi-sealed equipment spaces requiring localized fire suppression

 

Installation and Use Notes

 

  • Install according to the technical specification and prepare proper safety measures during installation.
  • Do not aim the discharge outlet toward people during installation or use.
  • Check the matched activation device while the extinguishing device is in normal working condition.
  • Before activation, confirm the discharge outlet is sealed and the protective cap has not fallen off.
  • Do not install in environments exposed to rain, water splash, acid or alkali corrosion, or strongly corrosive gases.
  • After device activation, clean the protected area within 24 hours and contact the supplier if technical support is required.

 

Related Technical Standards

 

Referenced standards in the source material include XF 499.1-2010, Q/JAD 002-2018, EN 15276-1:2019, and EN 15276-2:2019.

 

Model Selection Notes

 

When selecting a model, confirm the protected space volume, enclosure structure, installation method, wiring layout, activation method, ambient temperature, and required appearance style. Fire protection design should be reviewed according to applicable local regulations and project requirements.

 

Request a Quote

 

Need help choosing an aerosol fire extinguishing device for your equipment enclosure? Send the protected volume, application scenario, installation method, preferred style, quantity, and any certification or documentation requirements. Our team can provide model guidance, technical data, and quotation options.

 

Hot Tags: automatic aerosol spray fire extinguisher, China automatic aerosol spray fire extinguisher manufacturers, suppliers, factory, Automatic Aerosol Spray Fire Extinguisher, current limiting fire protector, Fireproof Current Limiter