Product Overview
The HGL series is designed for AC 50Hz industrial power distribution systems with rated working voltage up to 600V and rated working current up to 3150A. It provides electrical isolation and can switch rated loads, making it suitable for distribution cabinets, machinery panels and maintenance isolation points.
The switch uses a glass-fiber reinforced unsaturated polyester resin shell, a spring energy-storage acceleration mechanism and two parallel separable contacts. Its blade-type elastic contact structure provides pressure connection, clear opening and closing limits, and visible status indication for safer operation.
Key Features
- Suitable for AC 50Hz low-voltage distribution systems up to 600V.
- Rated working current range up to 3150A for industrial distribution applications.
- Provides both electrical isolation and rated-load switching capability.
- Glass-fiber reinforced unsaturated polyester resin shell improves insulation and mechanical strength.
- Spring energy-storage acceleration mechanism supports fast opening and closing action.
- Parallel separable contacts and blade-type elastic pressure connection support reliable conductivity.
- Clear 0/1 handle and observation-window indication improves operation visibility.
- Supports internal cabinet operation and external cabinet handle operation depending on model.
- Suitable for industrial enterprises, switchboards, control cabinets and power distribution systems.
Main Technical Specifications
|
Parameter |
Specification |
Notes |
|
Product Series |
HGL |
Manual isolation switch series |
|
Rated Frequency |
AC 50Hz |
Industrial distribution use |
|
Rated Working Voltage |
Up to 600V |
Based on supplied operation manual |
|
Rated Working Current |
Up to 3150A |
Model-dependent selection |
|
Conventional Free Air Thermal Current |
16A to 3150A |
Full series range |
|
Power Frequency Withstand Voltage |
2000V / 2200V |
Depends on current rating |
|
Rated Insulation Voltage |
800V / 1000V |
Model group dependent |
|
Rated Impulse Withstand Voltage |
12kV at 2000m |
Uimp reference |
|
Rated Short-Time Withstand Current |
2kA / 12kA / 20kA / 25kA / 50kA |
Depends on current rating |
|
Mechanical Life |
8000 / 5000 / 3000 / 1000 operations |
Depends on frame current |
Current Range Reference
|
Current Group |
Typical Ratings |
Technical Notes |
|
Small frame |
16A, 25A, 32A, 60A, 63A |
Compact isolation positions and branch circuits |
|
Medium frame |
80A, 100A, 125A, 160A, 200A, 250A, 315A |
Distribution feeders and equipment isolation |
|
Large frame |
400A, 500A, 630A, 800A, 1000A, 1250A, 1600A |
Main distribution and high-load cabinet applications |
|
High-current frame |
2000A, 2500A, 3150A |
Main incoming and high-capacity isolation circuits |
Normal Working Conditions
- Ambient air temperature: upper limit +40C, lower limit -5C, and 24-hour average not exceeding +35C.
- Installation altitude should not exceed 2000m.
- Relative humidity should not exceed 50% at +40C; up to 90% is allowed at +20C with condensation prevention.
- Pollution degree: Level III.
- Installation category: III or IV according to the application environment.
- For special low-temperature or special installation conditions, technical confirmation is recommended before ordering.
Operation and Maintenance Notes
The switch should be installed vertically and verified against nameplate requirements before installation. When the handle arrow and observation window show 0, the switch is open; when they show 1, the switch is closed.
- Terminals and connecting nuts should be insulated to prevent phase-to-phase short circuit.
- For external cabinet operation, the extension shaft must be coaxial with the handle hole.
- Routine maintenance is recommended approximately every six months.
- If rotating parts are stiff, apply suitable grease and check all fasteners.
- Stop using the product immediately if severe damage is found.
Typical Applications
- Industrial enterprise power distribution systems
- Low-voltage distribution cabinets and switchboards
- Main incoming and outgoing feeder isolation
- Machinery and equipment maintenance isolation
- Control cabinets requiring visible open/close indication
- Internal or external cabinet manual operation systems
Installation and Selection Notes
Select the model according to rated current, rated voltage, pole configuration, operating mode, cabinet depth and required handle type. For external cabinet operation, confirm extension-shaft length, panel drilling dimensions and handle alignment before installation.
- Confirm whether internal cabinet operation or external cabinet operation is required.
- Choose the current frame according to the load and short-time withstand requirement.
- Verify installation dimensions before cabinet drilling or panel processing.
- Installation and maintenance should be performed by qualified electrical personnel.
Why Choose the HGL Series
The HGL series combines robust insulation materials, a fast spring operating mechanism and clear position indication for reliable manual isolation. It is a practical choice for industrial power distribution projects that need load switching, visible isolation and flexible cabinet operation.
Ordering Information
When requesting a quotation, please provide product name, model, specification, quantity, operating method, cabinet installation requirements and any special environmental conditions. For custom installation scenarios, provide technical drawings or cabinet data for confirmation.
Hot Tags: load break isolating switch, China load break isolating switch manufacturers, suppliers, factory, Load Break Isolating Switch, Load Isolating Switch, load isolator switch