Product Overview
The HH15/QSA series is designed for AC 50Hz low-voltage distribution circuits with rated voltage up to 660V and rated current up to 3150A. It is used for switching normal loads, disconnecting overload current and providing isolation when the device is in the open position.
By combining a manual switch structure with fuse protection, the product helps electrical panels achieve visible isolation and short-circuit protection in one compact assembly. In short-circuit conditions, the fuse element interrupts the fault current, supporting safer operation and maintenance of power distribution equipment.
Key Features
- Integrated switch and fuse protection for low-voltage power distribution systems.
- Suitable for AC 50Hz circuits with rated voltage up to 660V.
- Rated current range up to 3150A according to the supplied manual.
- Supports connection and disconnection of normal load and overload current.
- Fuse protection interrupts short-circuit current and improves system safety.
- Open position provides isolation function for inspection and maintenance.
- Manual operating structure with selectable pole and auxiliary-contact options.
- Designed for low-voltage cabinets, feeder circuits and distribution equipment.
- Referenced standards include GB/T14048.3-93 and JB8629-1997.
Main Technical Specifications
|
Parameter |
Specification |
Notes |
|
Product Series |
HH15 / QSA |
Isolation switch-fuse assembly |
|
Rated Frequency |
AC 50Hz |
Low-voltage distribution circuits |
|
Rated Working Voltage |
Up to 660V |
Based on supplied manual |
|
Rated Current |
Up to 3150A |
Model-dependent selection |
|
Rated Insulation Voltage |
1000V |
Reference from technical table |
|
Function |
Switching, overload disconnection, fuse short-circuit protection, isolation |
Integrated panel protection role |
|
Operating Method |
Manual operation |
Operating torque depends on current rating |
|
Pollution Degree |
3 |
Installation environment reference |
|
Installation Category |
IV for Ie > 160A; III for Ie < 125A |
Overvoltage category reference |
|
Standards |
GB/T14048.3-93, JB8629-1997 |
Supplied manual reference |
Rated Current Selection Reference
|
Voltage Class |
Rated Current Range |
Typical Fuse Current Matching |
Application Note |
|
380V |
63A to 630A |
63A, 100A, 125A, 160A, 200A, 250A, 315A, 400A, 630A |
Common low-voltage feeder and branch circuits |
|
660V |
63A to 425A |
63A, 80A, 100A, 160A, 200A, 250A, 315A, 425A |
Higher voltage low-voltage distribution projects |
|
Extended Series |
Up to 3150A |
Project dependent |
High-current switch-fuse disconnector assemblies |
Operating and Auxiliary Contact Data
|
Item |
Reference Value |
Notes |
|
Manual Operating Torque |
7.5 / 16 / 30 N.m |
Typical values for 63-125A, 160-400A and 630A groups |
|
Auxiliary Contact AC-15 |
380V, 10A |
Reference control-circuit rating |
|
Auxiliary Contact DC-13 |
220V, 1A |
Reference control-circuit rating |
|
Electrical Durability |
Approximately 2000 operations |
Based on auxiliary-contact data table |
|
Mechanical Operating Interval |
300ms / 2000ms reference |
Depends on operating condition and category |
Normal Working Conditions
- Ambient air temperature should not exceed +40C, with 24-hour average not exceeding +35C.
- Minimum ambient temperature is -5C under normal conditions; special low-temperature use should be confirmed before ordering.
- Installation altitude should not exceed 2000m.
- Relative humidity should not exceed 50% at +40C; higher humidity is allowed at lower temperature with condensation prevention.
- The installation environment should match pollution degree 3 requirements.
Application Areas
- Low-voltage distribution cabinets and switchboards
- Main incoming and outgoing feeder protection
- Motor, transformer and branch circuit isolation positions
- Industrial power distribution and maintenance isolation circuits
- Commercial building low-voltage electrical systems
- Electrical panels requiring integrated fuse protection and visible isolation
Installation and Selection Notes
Select the device according to rated voltage, rated current, fuse size, number of poles, auxiliary-contact requirement and installation category. The fuse link must be matched to the protected circuit so that overload and short-circuit protection coordination is maintained.
- Confirm the prospective short-circuit current and fuse breaking capacity before selection.
- Choose the correct pole configuration and auxiliary contact quantity according to the cabinet control design.
- Verify operating handle clearance and mounting dimensions before panel production.
- Installation and maintenance should be carried out by qualified electrical personnel.
Why Choose the HH15/QSA Series
The HH15/QSA series gives panel builders a practical solution for load switching, fuse-based short-circuit protection and isolation in one device. It is suitable for low-voltage projects where dependable manual operation, clear circuit separation and compact protection design are all important.
Ordering Information
When requesting a quotation, please provide the rated voltage, rated current, fuse matching requirement, pole number, auxiliary contact configuration, installation category and cabinet mounting dimensions. For special ambient temperature or high-humidity use, confirm the operating conditions before ordering.