Electronic Type Earth To Leakage MCCB

Send Inquiry
Electronic Type Earth To Leakage MCCB
Details
● Product Type: Electronic earth leakage molded case circuit breaker
● Rated Frequency: AC 50Hz
● Rated Working Voltage: AC 400V
● Rated Current Range: Up to 800A
● Frame Current Classes: 125/250A, 400/630A, 630/800A
● Current Adjustment: 0.4-1.0In adjustable
Category
Residual Current Circuit Breaker
Share to
Description

Product Overview

 

The Electronic Type Earth Leakage MCCB is designed for AC 50Hz low-voltage distribution systems that require reliable residual-current protection, overload protection, short-circuit protection, and intelligent operating feedback in one molded-case device. It is suitable for AC 400V circuits with rated current configurations up to 800A, helping protect people from indirect contact while reducing fire risk caused by insulation failure, grounding faults, and leakage current in electrical equipment. For projects that need safer power distribution with digital monitoring, this product offers a practical solution for industrial cabinets, commercial power rooms, machinery panels, and building distribution systems.

 

Compared with a conventional molded case breaker, this electronic leakage protection unit uses a residual-current detection circuit and LCD display interface to improve visibility of operating conditions. The adjustable protection settings allow engineers to match the breaker to real load requirements, while optional communication functions such as RS485 support centralized monitoring and smarter electrical management. The product is built for distribution protection and infrequent line switching, and may also be used for infrequent motor starting where the selected frame, release type, and protection settings match the application.

 

Key Features

 

  • Electronic residual-current protection for ground-fault and leakage-current safety in AC distribution circuits.
  • Integrated overload and short-circuit protection to help protect cables, power supply equipment, and downstream loads.
  • LCD display design for easier viewing of operating status, setting information, and fault-related data.
  • Adjustable rated current range, commonly 0.4-1.0In, allowing more flexible coordination with the actual protected load.
  • Multiple frame current ranges, including 125/250A, 400/630A, and 630/800A classes for different cabinet designs.
  • Selectable residual-current operating settings to match different leakage-protection requirements and reduce nuisance tripping.
  • Optional delay characteristics for better selectivity in multi-level distribution systems.
  • RS485 communication terminals available for remote monitoring or integration with energy-management systems.
  • Complies with GB/T 14048.2 requirements for low-voltage circuit breaker applications.

 

Technical Specifications

 

Parameter

Specification

Product Page Notes

Product Type

Electronic earth leakage molded case circuit breaker

For residual-current, overload, and short-circuit protection

Rated Frequency

AC 50Hz

Suitable for low-voltage AC distribution systems

Rated Working Voltage

AC 400V

Used in three-phase low-voltage power distribution

Rated Current Range

Up to 800A

Select according to frame size and actual load current

Frame Current Classes

125/250A, 400/630A, 630/800A

Multiple cabinet and project configurations available

Current Adjustment

0.4-1.0In adjustable

Helps match breaker protection to load demand

Pole Options

3P / 4P

Use the correct pole configuration for the wiring system

Residual Current Settings

Multiple settings such as 50mA to 1000mA, depending on configuration

Choose based on personnel protection, equipment protection, and leakage level

Residual Current Delay

Instantaneous and delayed options available

Improves selectivity in upstream/downstream protection

Breaking Capacity Class

M / H high-breaking versions available

Final value depends on selected frame and specification

Communication

RS485 interface terminals

Supports monitoring and parameter management in intelligent systems

Standard

GB/T 14048.2

For low-voltage switchgear and controlgear circuit breaker requirements

 

Working Environment

 

For stable operation, the breaker should be installed in a dry, ventilated electrical enclosure without explosive hazards, corrosive gas, conductive dust, severe vibration, or direct exposure to rain and snow. The installation altitude should generally not exceed 2000m. Normal ambient temperature should remain within the specified product operating range, with attention to condensation when humidity is high or temperature changes quickly. The upper terminals should be connected to the power supply side and the lower terminals to the load side. The installation angle should be kept within the allowable tolerance specified by the product instructions.

 

Structure and Working Principle

 

The product uses an electronic residual-current protection structure. Its main components include the molded case breaker body, overcurrent release, zero-sequence current transformer, electronic control board, residual-current release mechanism, LCD display module, test function, and communication terminals. Under normal operation, the vector sum of the phase and neutral currents remains balanced. When insulation damage, grounding failure, or electric leakage occurs, the zero-sequence transformer detects the residual current and sends a signal to the electronic circuit. Once the signal reaches the preset operating value, the release mechanism trips the breaker and disconnects the protected circuit.

 

Recommended Applications

 

  • Main and branch distribution cabinets in commercial and industrial facilities.
  • Low-voltage power distribution systems requiring earth leakage and overcurrent protection.
  • Machinery, pumps, production equipment, and motor control circuits with infrequent starting.
  • Building power rooms, workshops, warehouses, and infrastructure electrical panels.
  • Projects requiring LCD status display, adjustable leakage settings, or RS485 monitoring capability.

 

Installation and Use

 

Installation, wiring, commissioning, and maintenance must be performed by qualified electrical personnel. Before installation, check that the nameplate data, rated current, rated residual operating current, pole number, accessory configuration, and breaking-capacity class meet the project requirements. Operate the handle several times before energizing to confirm that the mechanism moves smoothly without jamming. During wiring, connect the line side and load side according to the terminal markings; reverse connection or incorrect neutral wiring may cause malfunction or loss of protection. Use conductors or busbars with a suitable cross-sectional area for the selected rated current, and tighten all terminals according to electrical installation practice.

 

Important Selection Notes

 

For three-phase four-wire systems, select the proper 4-pole product configuration so the neutral conductor passes correctly through the residual-current detection system. Do not ground the load-side neutral wire, as this can cause unwanted tripping. When long cable runs or equipment capacitance create natural leakage current, choose the residual-current setting carefully to balance safety and system continuity. The test button should be used periodically to confirm the residual-current protection function. If the breaker fails to trip during testing, it should be removed from service and replaced or inspected by qualified personnel.

 

Request a Quote

 

For project selection or bulk purchasing, please provide the required rated current, frame size, pole configuration, residual-current operating value, delay requirement, breaking-capacity level, communication needs, accessory options, and order quantity. Our team can help confirm the suitable Electronic Type Earth Leakage MCCB configuration and provide product data, technical support, quotation details, and delivery information for your distribution project.

Hot Tags: electronic type earth to leakage mccb, China electronic type earth to leakage mccb manufacturers, suppliers, factory, AC High Breaking RCBO, AC Miniature Residual Current Circuit Breaker, Electronic Type Earth To Leakage MCCB, Molded Case Earth Leakage Circuit Breaker, residual current circuit breaker

Send Inquiry