Surge Protective Device

Send Inquiry
Surge Protective Device
Details
● Model: Range 10kA
● Uc: 275V / 320V / 385V / 440V
● Up: 1.5kV
● Imax: 10kA
● In: 5kA
Category
T2 Surge Protective Device
Share to
Description

Product Overview

 

The Surge Protective Device is designed for AC 50/60Hz low-voltage distribution systems with rated voltage up to 380V. It helps protect distribution circuits and connected equipment from lightning surge, switching overvoltage and transient voltage impact. Installed in a power distribution box or cabinet, the device discharges surge current to earth and limits the residual voltage to a safer level, reducing the risk of damage to meters, controllers, communication equipment, precision loads and other downstream electrical devices.

 

This series is available in multiple discharge capacity levels and pole configurations, making it suitable for residential, commercial and industrial power protection projects. The modular design supports 35mm DIN rail installation, while the visual indicator makes maintenance simple: green indicates normal operation and red indicates failure. For buyers looking for a practical surge arrester for distribution panels, this product provides reliable protection performance, easy installation and convenient module replacement.

 

Key Features

 

  • Designed for AC 50/60Hz low-voltage distribution systems with rated voltage up to 380V.
  • Protection against lightning surge, induced surge and grid switching overvoltage.
  • Multiple discharge capacity options: 10kA, 20kA, 30kA, 40kA, 60kA, 80kA and 100kA.
  • Available in 1P, 2P, 3P and 4P versions for single-phase and three-phase systems.
  • Visual status window: green for normal operation and red for module failure.
  • Optional remote signaling contact can be used for monitoring or alarm systems.
  • Compact modular design with 35mm standard DIN rail mounting.

 

Technical Specifications

 

Model Range

Uc

Up

Imax

In

Response Time

Leakage Current

10kA

275V / 320V / 385V / 440V

1.5kV

10kA

5kA

<25ns

<20uA

20kA

275V / 320V / 385V / 440V

1.5kV

20kA

10kA

<25ns

<20uA

30kA

275V / 320V / 385V / 440V

1.8kV

30kA

15kA

<25ns

<20uA

40kA

275V / 320V / 385V / 440V

1.8kV

40kA

20kA

<25ns

<20uA

60kA

275V / 320V / 385V / 440V

2.0kV

60kA

30kA

<25ns

<20uA

80kA

275V / 320V / 385V / 440V

2.2kV

80kA

40kA

<25ns

<20uA

100kA

275V / 320V / 385V / 440V

2.5kV

100kA

60kA

<25ns

<20uA

 

Class I Surge Options

 

Class I Rating

Power System

Uc

Iimp 10/350us

In 8/20us

Imax 8/20us

Temp.

15kA

220/385V 50Hz

220/385V

15kA

15kA

100kA

-40C to +80C

25kA

220/385V 50Hz

220/385V

25kA

25kA

150kA

-40C to +80C

35kA

220/385V 50Hz

220/385V

35kA

35kA

160kA

-40C to +80C

50kA

220/385V 50Hz

220/385V

50kA

50kA

200kA

-40C to +80C

 

Dimensions and Installation Options

 

Type

Module Width

1P Size

2P Size

3P / 4P Size

T1

36mm module

90 x 36 x 69mm

90 x 72 x 69mm

3P: 90 x 108 x 69mm; 4P: 90 x 144 x 69mm

T2

18mm module

89 x 18 x 62mm

89 x 36 x 62mm

3P: 89 x 54 x 62mm; 4P: 89 x 72 x 62mm

T2

27mm module

89 x 27 x 62mm

89 x 54 x 62mm

3P: 89 x 81 x 62mm; 4P: 89 x 108 x 62mm

 

Recommended Applications

 

  • Main low-voltage distribution cabinets in buildings.
  • Factory power distribution panels, machine rooms and workshop control cabinets.
  • Solar PV combiner boxes, energy storage systems and outdoor electrical equipment.
  • Data rooms, communication rooms, monitoring equipment and other sensitive electronics.
  • Branch distribution boxes requiring additional protection before terminal equipment.

 

Installation and Use

 

Installation should be completed by a qualified electrician after the upstream power supply has been disconnected. Mount the device on a 35mm DIN rail and install it after the main incoming switch or at the recommended lightning protection boundary. Wiring must follow the system diagram for the applicable TN-S, TN-C, TT or other power system. The phase line, neutral line and protective earth must be connected according to the terminal markings. The grounding conductor should be short and straight; total connection length is recommended to be less than 0.5m to reduce inductive voltage drop during surge discharge.

 

A suitable backup fuse or circuit breaker should be installed upstream according to project design. After energizing the system, check the indicator window. Green means normal operation. Red means the module has failed and should be replaced immediately.

 

Maintenance and Replacement

 

Inspect the device during regular electrical maintenance and before thunderstorm seasons. Confirm that the status window is green, terminals are tight, the enclosure is not deformed and there is no abnormal heating or burning mark. After a severe lightning event, inspection should be performed even if no visible failure is found. If the indicator turns red, disconnect the power supply and replace the module with the same specification.

 

Selection Notes

 

When selecting a surge protection device, confirm the system voltage, grounding system, pole configuration, discharge current level, voltage protection level and installation position. Higher discharge capacity is recommended for main incoming cabinets, outdoor distribution systems and sites with higher lightning exposure. Branch distribution boxes can use medium or lower discharge capacity according to the risk level and coordination design.

 

Request a Quote

 

For project selection or bulk purchasing, please provide the required voltage, pole configuration, discharge capacity, grounding system, installation position and order quantity. Our team can help confirm the suitable Surge Protective Device configuration and provide technical data, quotation support and delivery information.

 

Hot Tags: surge protective device, China surge protective device manufacturers, suppliers, factory, Class I II Surge Protective Device, T2 High Discharge Current Surge Arrester, t2 surge protective device, T2 Surge Protective Device With Fuse, T2 Surge Protective Device With LED Indicator

Send Inquiry