Product Overview
This three-phase electronic active energy meter is designed for precise AC energy measurement in power utilities, factories, enterprises, commercial installations, and agricultural power systems. It uses a dedicated large-scale integrated circuit, 16-bit A/D conversion, digital multiplication, digital sampling processing, and SMT manufacturing technology to deliver stable and reliable metering performance.
The product supports three-phase active energy measurement at 50Hz and uses a clear LCD display for convenient on-site reading. According to the supplied specification, it can accurately measure forward and reverse active energy, while offering strong electromagnetic interference resistance, low power consumption, anti-tamper performance, wide load range, and long service life.
Key Features
- Three-phase active energy measurement for utility, industrial, commercial, and agricultural applications.
- Supports bidirectional active energy metering with accurate and stable digital processing.
- LCD energy display provides clear readings for inspection and billing support.
- One-phase or two-phase power loss does not affect measurement accuracy under three-phase supply conditions.
- Low power consumption, good electromagnetic interference resistance, and anti-tamper design.
- Optically isolated passive pulse output supports external metering and data acquisition.
- Three LED phase indicators help identify A, B, and C phase loss conditions.
- Designed in line with GB/T 17215.321-2008 and IEC 61036:2000 reference standards.
Main Technical Specifications
|
Item |
Specification |
|
Product type |
Three-phase electronic active energy meter |
|
Frequency |
50Hz AC three-phase active energy measurement |
|
Accuracy class |
Class 1 or Class 2 depending on model |
|
Reference voltage options |
3x220/380V, 3x57.7/100V, 3x100V, 3x380V |
|
Direct current ratings |
10(40)A, 15(60)A, 20(80)A, 30(100)A |
|
Transformer-type current rating |
1.5(6)A |
|
DIN rail current rating option |
5(100)A |
|
Connection type |
Direct connection or transformer connection |
|
Meter constant |
Direct type 200 imp/kWh; transformer type 1600 imp/kWh |
|
Display |
7-digit LCD, 6 integer digits plus 1 decimal digit |
|
Voltage operating range |
Normal 0.9Un-1.1Un; limit 0.7Un-1.15Un |
|
Power consumption |
Voltage circuit <=2W (10VA); current circuit <=4.0VA |
Accuracy and Performance Reference
|
Reference Item |
Details |
|
Balanced load accuracy |
Class 1 and Class 2 accuracy limits according to current range and power factor conditions |
|
Unbalanced load accuracy |
Class 1 +/-2.0%; Class 2 +/-3.0% |
|
Starting current |
0.004Ib for class 1; 0.005Ib for class 2 |
|
Creep performance |
No more than one output pulse with 1.15 times reference voltage and no current |
|
Supply reliability |
Can operate normally with any single-phase power supply present in a three-phase system |
Functions and Output
- Active energy metering function for three-phase systems.
- Forward and reverse active energy measurement using a dedicated metering module.
- Optocoupler-isolated passive pulse output interface.
- Three phase-loss indicators for A, B, and C phases.
- LCD display supports direct reading and convenient meter inspection.
Environmental and Mechanical Data
|
Item |
Specification |
|
Normal operating temperature |
-10°C to +45°C |
|
Limit operating temperature |
-25°C to +55°C |
|
Storage and transport temperature |
-25°C to +70°C |
|
Relative humidity |
Annual average <=75% |
|
Overall dimensions |
228mm x 145mm x 72mm |
|
Weight |
Approx. 1.5kg |
|
Installation guidance |
Indoor installation recommended; outdoor use requires a protective meter box |
|
Recommended installation height |
About 1.8m |
Typical Applications
This electronic energy meter is well suited to projects that need dependable three-phase active energy measurement with convenient installation and visible local readout.
- Power utility metering systems
- Factory and industrial distribution panels
- Commercial building energy measurement
- Agricultural power distribution applications
- Lighting and motive power equipment monitoring
- Three-phase feeder and branch circuit energy recording
- Projects requiring pulse output for remote data collection
Installation and Ordering Notes
- Confirm whether the project needs direct connection or transformer connection before ordering.
- Select the correct reference voltage and rated current according to the system design.
- Check the required accuracy class and pulse constant for the application.
- Install the meter according to the terminal wiring diagram and tighten all terminal screws correctly.
- Keep the seal intact and use qualified personnel for installation, verification, and maintenance.
- Store the product in its original packaging in a clean environment free from corrosive substances.
Request a Quote
Send us your voltage system, current rating, connection method, accuracy requirement, and project quantity, and we will recommend the right three-phase metering configuration for your distribution or billing application.
Hot Tags: rail mounted energy meter, China rail mounted energy meter manufacturers, suppliers, factory, electric meter, Electronic Energy Meter, Prepaid Meter With IC Card, Rail Mounted Energy Meter, Three Phase Four Wire Electronic Prepaid Energy Meter, Three Phase Four Wire Multifunction Energy Meter